In China Meteorological Department, for mine detection, mine engineering, has been using the traditional manual management of paper files. In need of long-term preservation of the mine business information as a large number of documents, a wide range of needs not only larger and better place to store, but also to spend a lot of manpower for maintenance and management. However due to natural and human factors as well as old age and other reasons, there will always be a number of image file loss or damage to varying degrees. More importantly, each time to browse, borrow, sorting, classification, examination and approval, archiving, and so is very inconvenient. In order to address these many problems, the urgent need to implement an electronic document management. Computer was used to mine information management office, with manual management incomparable advantages. For example: quick search, find convenient, high reliability, large memory capacity, security and good, long life and low cost. These advantages can greatly improve the efficiency of the management of mine operations. Therefore, developing such a business management software has become a necessary thing. In this paper, mine operations management system, operating system platform selection, development environment, design, back-end database design, architecture choices and realize the B / S architecture, technology and information management systems programming carried out in-depth research, design and development of a set of WEB-based mine operations management system. The development of functional modules include: mine law enforcement, project management, test management, and construction of pre-trial management, remote monitoring, system management, user and rights management capabilities module. At present, the basic completion of the development of the system and their functions in line with customer needs, able to complete the demand for all kinds of information requested in the input, query and statistics, and various related reports printing. And provides system maintenance functions, allowing users to facilitate data backup, restore, and delete. This system ** City Mine Disaster Reduction Center has been put into use more than six months time, the user response is good, business management of the mine provides a great convenience.

在我国气象部门,对于防雷检测、防雷工程等,一直采用传统的人工方式管理文件档案。对需要长期保存的防雷业务信息由于文档数量庞大、种类繁多,不仅需要较大和较好的场所来储存,而且需要花大量的人力进行维护管理。尽管如此由于自然环境和人为因素以及年代久远等原因,总会有一些图档流失或不同程度的损坏。更为重要的是,每次浏览、借阅、整理、分类、审批、归档等都十分不方便。为了解决上述诸多问题,迫切需要实施文档的电子化管理。Manpower way administration document file always adopt tradition to lightning protection detecting , lightning protection project etc. in our country meteorological department . Kind is numerous to needing the lightning protection business information that the long range preserves since document quantity is ample,not only requiring that big and fairly good lieu comes to store up, and the manpower go along upkeep needing to spend a great quantity manages. Although waiting for cause since the natural environment and the artificial factor are as well as age-old this way,the general association pursues the run off or to varying degrees breakdown of archives a little bit. Be important being more , browse , borrow each time go over, arranging , classifying and examining and approving, filing and so on does not go to the lavatory all very. For resolving as said or narrated above a lot of problems, urgent need puts electronization document administration into practice.利用计算机对防雷办公信息进行管理,具有手工管理所无法比拟的优点。例如:检索迅速,查找方便,可靠性高,存储量大,保密性好,寿命长,成本低等。这些优点能够极大提高防雷业务管理的效率。因此,开发这样一套业务管理软件成为很有必要的事情。The information go along making use of a computer to handle official business to lightning protection is managed , is has unable parallel handwork administration merit. For example: The retrieval is prompt , seek reliability is high , store reserves conveniently, to keep secret greatly, nature is good , life-span is long , cost waits low. These merit can the maximum improves the efficiency that lightning protection business manages. The management software therefore, developing such set of business becomes the thing being necessary very much.本文在防雷业务管理系统的操作系统平台选择、开发环境设计、后台数据库设计、架构选择、实现B/S架构的技术和信息管理系统的程序设计方面进行了深入的研究,设计开发了一套基于WEB的防雷业务管理系统。开发的功能模块主要包括:防雷执法、工程管理、检测管理、建审管理、远程监测、系统管理、用户及权限管理功能模块等。The platform in lightning protection business management system chooses the main body of a book , exploitation environment designs , the data base designs on the backstage , the frame chooses B/S frame technology and information management system , realizes programming aspect be in progress thorough go into, design develop the same stuff WEB-based lightning protection business management system. The development function module is included mainly: Guard against thunder enforcing the law, schedule control, checks administration , build to try administration, long-range monitor, system administration , consumer and the module managing a function within the power of etc.目前,该系统基本开发完毕,其功能符合了客户的需求,能够完成需求中要求的各种信息的输入,查询和统计,以及各类相关报表的打印。并提供了系统维护的功能,使用户方便进行数据备份、恢复和删除。本系统在**市防雷减灾中心投入使用已经有半年多的时间,用户反应良好,对防雷业务管理提供了极大的方便。 At present, fundamental exploitation of that system has been finished , whose function has conformed to customer's need, the entering being able to accomplish the various information demanding in need , the printing inquiring about and counting, as well as of all kinds the relevance form for report's. Have provided system upkeep function and , have made a consumer carry out the data back-up conveniently , have recovered and have deleted. Originally, system is put in use in city lightning protection disaster alleviation centre * * already having much time the half a year , consumer reaction is fine , business manages to lightning protection to have provided immense going to the lavatory.可以吗

推广与普及气象科技,是建设社会主义新农村不可分割的一部分,我为大家整理的气象科技论文 范文 ,希望你们喜欢。 气象科技论文范文篇一 气象科技在社会主义新农村建设中的作用 摘要:推广与普及气象科技,是建设社会主义新农村不可分割的一部分,其作用将直接影响农民的切身利益。作为气象工作者,我们要想农民之所想,急农民之所急。把气象科技知识运用到建设社会主义新农村的工作中去。 关键词:社会主义新农村;农业现代化;宣传气象科技;灾害性天气;考核评估 0 引言 农村现代化建设首先要提高广大农民的科技现代化的素质水平,创建科技学习型农村是建设社会主义新农村的重要组成部分。党中央提出要建设社会主义新农村的伟大号召,是非常符合中国国情的。我国是个农业大国,80%以上的人口都集中在农村,把中国农村建设好,是富国富民的根本出路。在这种形势下,同样要求气象部门为建设社会主义新农村办实事,做贡献。根据衢州的实际情况分析,为了充分发挥气象科技的独特优势,积极配合市委,市政府及有关部门为建设社会主义新农村,做出我们应尽的贡献。 1 明确建设社会主义新农村中气象科技的工作目标 根据建设社会主义新农村的要求和衢州农村工作的实际情况,气象科技服务的主要目标是以建设经济发达,行为文明,环境优美,产业水土结构配置合理,不断改善小气候环境,推进社会主义新农村建设,最终实现农业现代化的目标。这就要求广大的气象工作者,重视气象科技在建设社会主义新农村中的重要性。要把气象科技为农村和农业服务工作落到实处。农业气象是我们气象部门多年研究的主要学科,在建设社会主义新农村中就要把我们气象科研成果应用到新农村建设中去。 2 创建气象科技在建设社会主义新农村的工作载体 在气象科技为建设社会主义新农村的过程中,要根据衢州市农村经济发展的实际情况和农村中不同人群的不同需要开展气象科技宣传活动。要精心设计并运用好各种载体开展气象科技宣传活动。 可开展“流动气象科技宣传日”活动 不定期的流动到各乡镇或村宣传气象科技,围绕着“气象与自然”“自然与人”这样的主题,创新气象科技宣传形式,丰富气象科技宣传的内容,深入浅出,使广大农民能够听得懂,用得上。 结合政府“三下乡活动”开展气象科技传播活动 这就是由乡镇在农村集镇组织开展农村实用技术知识宣传,农村实用科技图书销售和科技致富家庭结合等活动中开展气象科技知识的宣传。 通过衢州的农技110平台开展气象科技的宣传活动 用网络宣传和推广气象科技是一条非常好的 渠道 。现在网络已通到广大农村,而农技110也是在衢州农村中家喻户晓,我们可以借助这个平台,开展气象科技为农业和农村服务活动,推动高效生态农业的发展。 用群众性读书活动来开展气象科技的宣传 组织开展村镇“读书服务日”活动,送一些气象科普书籍到村镇,建立村镇读书小组,在一些有条件的村镇开展气象科技知识讲座活动,吸引广大农民关心气象,重视气象,应用气象知识为社会主义新农村建设服务。 3 推进气象科技知识在农村的普及 在建设社会主义新农村过程中,气象部门要充分发挥自己的科技优势,这就要突出以邓小平理论,江泽民“三个代表”重要思想和胡锦涛同志“八荣八耻”要求为核心的社会科学知识的份量。 提高农民群众的思想道德素质和人文素质 要强调政治理论和 法律知识 的学习,这是我们在社会主义新农村建设中普及气象科技的指导思想。 将气象科技知识应用到实践中去 用气象科技知识结合衢州农村的实际情况,讲解一些灾害性天气形成的原理和过程,教会广大农民如何应对灾害性天气。比如:衢州是柑桔之乡,主要经济作物就是柑桔,但桔树不扛冻,冻害发生时,很多桔树就要冻死,结合这种实际,告诉 种植 户们冻害是如何形成的,怎样防冻,用人工的形成如何解除冻害等。以及在雷雨多发季节,普及一些雷电的防范知识等。 气象科技与人类的生存有着密切的关系 在建设社会主义新农村中,把气象科学知识普及到广大农村中,有着非常重要的意义。 4 建立气象科技在建设社会主义新农村中的考核评估体系 为了推进气象科技在建设社会主义新农村中做贡献能够深入开展。我们应该注意探索气象科技知识普及型村镇建设的长效管理机制,建立相对完善的气象科技普及型村镇建设的考核评估体系。 将评估标准具体化 要从组织领导、载体建设、设施完善、培训有续、信息沟通、实际成果等六个方面提出考核评估标准。 讨论学习,积累 经验 在开展示范点达标的工作中,要及时 总结 经验,对工作中出现的问题要及时展开分析讨论以达到解决问题的目的。不断推进气象科技在建设社会主义新农村中的作用,使气象科技为建设社会主义新农村制度化、规范化、经常化服务。 5 气象科技要为新农村建设做出应有的贡献 气象是一门学术科学,同时也是一门应用科学。气象科技研究的直接成果就是要应用到 社会实践 中去。在建设社会主义新农村中就是要把气象科技产品直接应用到农业生产中。 通过气象科技的宣传提高农民的科技素质 要使广大农民在气象科技宣传和应用中自身素质得到普遍提高。要使广大农民知道气象科学的一些基本原理,懂得如何应对突发性、灾害性天气。 建立相关设施,使气象科技发挥其应有的作用 要有计划地、逐步地在乡镇建立天气预警电子显示屏,其目的就是在第一时间将气象科技产品及气象信息送到用户手中,使乡镇第一时间了解气象,从而使乡镇的形象在气象科技服务活动中得到整体提升。 要使气象科技更好地为农村服务 我们要用先进的气象科技手段服务于社会主义新农村的建设。人工影响天气在衢州得到落实,这就是气象部门为社会主义新农村建设办的又一件实事。应用先进的气象科技技术服务社会,达到减灾防灾的目的。 作者简介:栗建勇(1954-),男,中专,浙江省衢州市气象局工程师,从事气象科技服务工作。 气象科技论文范文篇二 气象科技服务对公共气象服务的促进和发展思考 [摘要]气象信息在我国的社会经济发展和人们的日常生活中都有着重要的作用,随着社会经济的不断发展和科学技术的进步,我国的气象监测技术得到了迅速的发展。人们生活水平的不断提高,对公众气象信息服务的要求越来越高。因此,气象信息服务部门应该根据发展现状,采取有效的 措施 提高公众气象信息的服务发展水平,以适应人们日益增加的需要。 [关键词]公众 气象 信息服务 发展 思考 分析 中图分类号: P4 文献标识码: A 前言 现代生活中互联网的广泛应用,已经引起了气象科技服务形式和 方法 的变化,然而随着科学技术水平的进一步提高,必然会有更进一步的创新。公共气象服务的不断发展,需要良好的气象科技服务。这要求气象从业者不但要了解气象科技服务进步带来的积极影响,还要努力满社会需求。只有这样,才能为公共气象服务健康、良好的发展奠定基础。 1 气象科技服务对公共气象服务的促进作用 有利于公共气象服务平台的创建和气象信息覆盖范围的扩大 公共气象服务是各种气象服务的最初目的,也是最终目标,而且作为政府公共服务体系中非常重要的组成部分,公共气象服务对社会有着非常大的影响。只有气象科技服务水平不断提高,山东省的公共气象服务才能不断完善。另外,社会的发展、科技的进步使气象科技服务水平不断地提高,从单一的广播播报方式到广播、电视、网络相结合的播报方式,还有手机的短信气象服务,都使气象信息的覆盖范围不断扩大,越来越多的地区能随时随地了解天气情况。 广度上,扩大气象信息服务范围 改革开放三十多年来,我国的气象科技得到了前所未有的飞速发展,从简单的防雷检测到服务功能多样化,从单一的电台播报到电台、手机、互联网等多位一体,气象科技正往多样化的方向发展,气象信息随之走向了更广的范围。无论你身处何方,只要有网络或者手机信号的地方,都可以得到你想要的气象信息。 提供气象部门的防灾减灾服务 随着气候的不断变化,气象灾害频发,防灾减灾工作就十分重要。为了在灾害前,提示人们做好防灾减灾工作,气象部门在发布气象服务信息的时候,一定要提供相关的防灾减灾服务。例如,我国的气象局专门建立了气象灾害警示系统,对灾害性天气进行监测和预防。气象部门利用不同的信息传播方法,实现对气象信息和预警信息的及时发布,可以有效的减少气象灾害造成的损失。手机气象短信服务,在信息传输的渠道中,具有广泛的覆盖面,比较便捷,可以实现对气象信息的迅速传播,为气象信息服务的发展提供了良好的条件。 2 气象科技服务存在的问题 气象科技服务的公益性和盈利性问题 气象科技服务虽然属于公共气象服务,但是它并不是无偿的服务,而是属于盈利性的;而它又能利用各种科技知识,向社会提供气象信息,又具有一定的公益性,这两者具有对立统一的关系。如何处理好公益性和盈利性的关系,成了聊城市阳谷县气象局一个比较棘手的问题。当然只有尽最大可能地体现气象科技服务的公益性,才能使公共气象服务更加的完善。 . 市场机制尚未健全 不健全的市场机制是制约气象科技服务发展的又一大原因。不健全的市场机制主要表现为气象科技服务的运行机制与现有的市场经济体制不相适应,具体来说: 气象科技服务没有形成一套整体发展的规模,欠缺一些龙头企业以及一些主打产品的统领; 气象科技服务没有形成一个竞争和发展的环境,存在恶性竞争的现象; 气象科技服务欠缺资金以及人才方面的投入机制。 气象科技服务从业队伍的组建机制不合理 3市场竞争力不足 目前的气象科技服务还仅仅以气象部门为主,一些项目只是补偿性的收取些许费用,并不完全是市场行为,而商业性气象科技服务还没有得到发展,气象科技服务的市场还有待于培育和发展,目前气象科技服务的综合实力和市场能力仍旧相对薄弱,因此还不具备开发海外市场的条件,海外市场的份额还比较小。 4促进公共气象服务发展的措施 加大对气象科技服务的投资,促进气象科技服务的发展 气象科技服务的公益性是建立在其盈利性的基础之上的。想要处理好气象科技服务的公益性和盈利性问题,就得从资金问题入手,有了充足的资金,才能使气象科技服务部门设备的不断完善,才能确保气象服务人员的基本经济利益,才能使他们对气象科技服务更有信心且对工作充满积极性。政府加大对气象科技服务的投资,满足了气象科技服务的盈利性,其公益性才能更好地显现出来,才能切实促进公共气象服务的发展。 推进气象科技服务创新体系的建设 在行业管理方面,最主要的就是要不断推进创新体系的建设,通过不断加强各种气象科技服务资源的配置,不断融合行业的相关机构,最终形成一个优势互补、相互配合的气象科技服务体系,尽最大的努力开发利用一切可利用的气象科技服务的基础资源,不断进行创新,包括用人机制以及项目建设方面的探索与创新等,最终建立起一套各部门、各行业协调配合的高效运转体制。此外还需要建立一套关于气象科技服务及其实施效果的外部评价体系,对各种项目的实施进行合理的评价,不断引导科技服务项目的开发和利用,最终实现气象科技服务资源的合理配置。 加大对气象科技服务的投资,促进气象科技服务的发展 气象科技服务的公益性是建立在其盈利性的基础之上的。想要处理好气象科技服务的公益性和盈利性问题,就得从资金问题入手,有了充足的资金,才能使气象科技服务部门设备的不断完善,才能确保气象服务人员的基本经济利益,才能使他们对气象科技服务更有信心且对工作充满积极性。政府加大对气象科技服务的投资,满足了气象科技服务的盈利性,其公益性才能更好地显现出来,才能切实促进公共气象服务的发展。 加大投入,为气象科技的发展提供充足的财力支持 处理好气象科技服务公益性与盈利性之间的矛盾,一个必要条件就是加大国家对气象事业的财政投入。气象科技行业属于国家的事业单位,国家按照事业单位的管理办法来管理气象科技行业,但是,与其他事业单位不同的是,气象科技行业具有双重性质,它在社会中的特殊地位决定了社会公益性是其盈利性的前提。在国家财政投入不足的情况下,要求气象科技行业以社会公益性为前提,那么气象行业就没办法养活行业内部的从业人员,这样势必会造成气象科技从业人员的积极性。所以,为了确保气象科技行业从业人员的积极性,确保气象行业以社会公益性为前提,国家应相应地增加财政投入。 . 形成机制,增强竞争力 打造气象科技服务的全方位服务理念,拓展服务范围。可适当增加互联网、手机通讯等气象科技服务业务,在方便群众及时掌握气象信息的同时,增加市场占有份额,同时注重海外市场的投入与开发,增强竞争力。 5、结语 气象科技服务作为公共气象服务的重要组成部分,对公共气象服务的发展起着重要作用。当前我国的气象科技服务在取得了长足发展的同时存在着一些问题,本文立足于气象科技服务对公共气象服务的促进与发展作用,研究分析了二者间的关系,探讨了目前气象科技服务存在的问题,并提出了个人建议,以期促进气象科技服务与公共气象服务的协调发展。 参考文献 [1] 张鹏,杨秀华,杨秋利,等.新农村建设中气象服务的探讨[J].农技服务,2011(03). [2] 刘宇.在新形势下发展我省气象科技服务的思考[C].陕西省气象学会,陕西省气象学会2005年学术交流会论文集.2005(4). [3] 胡玉蓉.新形势对气象科技服务发展的思考[J].气象软科学,2008(3). 看了“气象科技论文范文”的人还看: 1. 关于科技论文范文 2. 关于雾霾的科技论文1000字 3. 1500字科学论文范文 4. 办公自动化论文范文3篇 5. 标准学术论文范文

电力系统防雷技术应用研究论文

摘要: 雷击对电力系统的破坏会产生严重后果,因而电力系统内外部的防雷要求也越来越高了。因为科技进步使得防雷技术不断发展,而雷电这种自然现象对电力系统的危害还是会一直存在,故而要想让电力系统安全供电,重点还是应该做好防雷工作。文章主要通过雷电对电力系统运行的影响论述来探讨电力系统防雷技术的应用,以期为电力系统的安全运行提供有益建议。

关键词: 电力系统;防雷技术;应用

作为自然现象之一的雷电会对电力系统造成击穿、线路损害、设备失灵等不同的损坏,而且还雷电涌流还会进入系统二次设备,让相关保护装置出现失灵之类的恶性事故,由此严重威胁电力系统的安全运行。也正是因为如此,人们一直在研究雷电及相关的防雷技术,通过大量的研究来研发更为有效的雷电保护装置,为电力系统的安全运行保驾护航。

1雷电与电力系统运行

尽管雷电属于自热现象,但是却是电力系统运行中的不可抗力,雷电是因为正电极存在负电荷而产生,能够在电场周围形成强大的高压,让空气绝缘被影响,受到损坏,而雷电间各种电极不断进行大量放电,尽管放电时间短且不会超过100,不过电流强度却高达100000A。闪电在放电中产生电火,在短时间内周围空气突然膨胀后爆鸣,从而产生了自然雷电现象。电力系统很容易被雷电所袭击,电力、设备与系统都会被电磁、热力影响,造成线路、电线等出现熔毁问题。并且电雷带来的高强度电压、电磁会极大影响电路与电线的绝缘体,只要存在高强度电压,电压强度就会很大,由此出现闪络问题,而这种问题在电力设备、线路等绝缘物体上发生就会让电力系统设备与线路出现损坏。尽管雷电会破坏电力系统的安全运行,不过只要采取合理的防范方法,就能够预防雷电灾害。当下,避雷针(线)安装、电力系统设备绝缘性提升、避雷保护装置设置等是比较常用的雷电防护措施。

2防雷技术在电力系统的应用

避雷器作为雷电流泄放通道,还可以被看成是等电位连接体,安装要对地,而在线路上并联,一般都处于高阻抗环境。雷击可以在一瞬间被避雷器导通,把雷电电流引向地上,同时让设备、线路、大地在等电位上,让电力系统不会因为强电势差而被损坏。雷击能量就打,只使用避雷器是无法完全把雷电流引入地上,也会损坏自身。所以,应该将功能不一样的避雷过压保护器件放置在各个电磁场强度空间。不同器件分工合作,让电流入地,保证低残压,也让避雷器的使用寿命更长。

电源系统防雷

所谓电源系统防雷就是利用避雷过压保护计算机系统电源与相关的交流配电部分,蒋避雷器安装在雷电波可能侵入的电力进线部位。电源系统有很多不一样保护级别。电源避雷器的'选择应该要与额定通流容量、电压保护水平相适应,让避雷器能够抵御雷电冲击。电影避雷器中残压特性十分重要,要想避雷器的保护效果更好就应该要使其残压更低。另外,必须兼顾避雷器能够具有很高的最大连续工作电压。原因就是如果最大连续额定工作电压不够高,避雷器会很快损坏。电源避雷器需要贴上失效警告指示,还有方便监管、维护的遥测端口。电源避雷器要有阻燃作用,防止失效与自毁情况下的起火问题。电源避雷器通常都具有失效分离装置。如果不能避雷就会自动断开电源系统,而且电源系统也会正常运行。在安装电源避雷器的过程中,要注意和电源系统的连接线越短越好,所使用的阻燃型多股铜导线的横截面面积不能超过25mm2,要紧密地并排,可以绑扎布放。避雷器接地线所使用的25mm2到35mm2的阻燃型多股铜导线,要么尽量就近入地,要么就近和交流保护接地汇流排或者直接和接地网连接。

通信系统防雷

一般数据线路上会串联接口避雷器,而且是以不影响数据传输作为应用依据。数据接口的工作带要宽、物理接口要合适,并且还要考虑到接口速率,以更好地保护避雷器。数据设备接口的连接为了增加插损,要少用转接方法,这样才可以让信号更好地传输。而在选择速率高的数据设备接口时,要考虑起驻波比、极间电容、漏电流小、响应时间快的数据避雷器。从信号工作电压层面选择动作电压、限制电压合理的数据接口,以保护避雷器。选择抗雷电冲击力强的数据避雷器时,应该要充分了解设备接口抗雷电要求。数据避雷器的接地连接一定要有效,就近连接接地线与被保护数据设备的地线,而接地线截面不能低于25mm2。

机房接地改造

接地系统在电力系计算机系统避雷过压保护技术中有十分重要的作用。防静电接地、防雷接地、保护接地等都属于接地技术。这些接地的用途、意义、要求都不一样,糖醋分设每个独立接地体是较为常见的,不过,由于雷击环境中,防雷接地系统和别的接地系统有电势差,所以很容易出现反击事故,让电子设备被损坏。所以,需要等电位连接全部接地系统。

3结语 总之,电力系统在不断发展,而且被运用在社会生产生活的各个行业,因此其作用极大。我国经济发展日盛,电量需求巨大,电力供应异常重要。因此,需要对电力系统进行有效保护。一直以来,雷击对电力系统的影响尤甚,因而电力系统中防雷技术的应用受到高度重视。在电力系统防雷技术应用中,我们必须要通过具体的实际情况来采取科学、有效的防雷措施。在对电力系统的防雷工作中,要积极地采取新技术新措施,保证电力系统的正常运行,为人们的生产生活创造安全、稳定的环境。

参考文献:

[1]张金国.电力系统防雷措施研究[J].科技创业家,2013(4):63

[2]王少先.电力系统防雷工程设计浅谈[J].科技资讯,2012(2):51

l论文检测

选择合适的查重软件,输入题目和作者及需要检测的论文内容(papertime目前是免费检测软件),比对数据库比较全面,重点是安全无痕检测。

毕业论文查重检测是整篇论文上传的,然后论文查重系统是会对整篇论文进行部分划分,所以毕业生上交的论文格式对论文查重率是有很大影响的。论文在查重检测时,不同段落的划分是会造成一部分文字检测不出来的,所以毕业论文想要顺利通过查重检测,是可以划分多个小段的,这样是可以降低论文查重率的。PaperFree在线改重功能实现了一边修改论文,一边论文查重,改哪里检测那里;按实际修改句子收费,不改的内容不收费;享受论文智能降重带来的美妙体验。

如果是初稿,可以先找一款靠谱的查重系统。然后上传论文,按提示付费后点击提交论文即可。等待半小时到一小时左右就会给出检测报告。如果是定稿检测,就要用学校要求的查重系统了。

我们对论文检测并不陌生。除了毕业生写的论文,发表的论文也需要检测。那么检测论文的步骤是什么?发表一篇论文还是有难度的。你的论文前提要足够新颖,除此之外,还要有研究价值。还有一个基本条件就是你的论文重复率要达到规定的要求。发表论文的检查流程与本科论文相同。您可以选择相同的检查系统进行重复检查。他没有强制要求使用哪种检查系统进行重复检查。但小编建议,你还是要选择市面上比较流行的,重复率比较准确的论文检测系统,这样才能保证你的论文重复率能达到规定的要求,重复率也比较准确。选择系统后,只需将需要查重的论文上传到系统,论文查重系统就会对你的论文进行查重。如果你连续重复13个单词,系统会用红色字体标记你的内容。这时候你只需要静静等待,检查结果就会以PDF或者网页版的形式显示出来。你可以根据测试报告中的信息修改论文。重复率达不到规定要求的,需要再次送审,直至重复率达不到规定要求,论文不能发表。

防雷接地装置设计及检测方法论文

防雷接地电阻测试方法:1、先确定避雷接地网上的接地线或是等电位上面联接箱子的位置;2、再拿测试机器测出电阻的实际数值,先把两个米的测试桩插进土,一根离测试点20米,另一根则是40米,确保测试点四周42米范围内有土;3、接地电阻的数值越小越好,具体数值看设计需求,没需求时要低于4欧。防雷接地分为两个概念,一是防雷,防止因雷击而造成损害;二是静电接地,防止静电产生危害。随着储罐阴极保护应用的日益广泛,其保护效果越来越多的受到人们的关注,防雷接地规范与阴极保护规范的矛盾也越来越突出。接地装置容易发生腐蚀的部位主要有:1、设备接地引下线及其连接螺丝;2、各焊接头;3、电缆沟内的均压带;4、水平接地体。防腐蚀措施:1、接地体采用铜材、铜包钢接地体或热镀锌材料;2、焊接处刷沥青漆或银粉漆;3、采用阴极保护。防雷接地测试注意事项:1、禁止在有雷电或被测物带电时进行测量。2、仪表携带、使用时须小心轻放,避免剧烈震动。

防雷接地是为了防止高层建筑物,通信基站,气象站,雷达站,石油气站等被雷直接击中的危险,先将雷引入地面,当高楼上空出现带电云层时,防雷装置通过静电感应,使得避雷导体的尖端聚集大部分的电荷,这样,避雷器和带点云层就形成了一个电容器,避雷器的顶端通常都比较尖,使得这个电容器的正对面积很小,电容也就小,能容纳的电容少,但是这里又聚集了很多的电荷,所以当电荷达到一定量时,避雷器和云层之间的空气就很容易被击穿,形成一个通路,将电荷导入大地,这样带电云层就不会对高层建筑构成危险。因此现在很高的层建筑物上都装有防雷接地的系统防御设施。那么防雷接地设施是怎么设置的呢?让小编我来详细的说明防雷接地是怎样施工的。

防雷接地方案措施需要详细的计划和安排,下面介绍一下防雷接地的安装方案和应该注意的事项。

安装方案

防雷接地,首先要探测周围的地形地貌,了解工程概况,然后进行材料,器具和人员的准备,如果是在室内用,室内用主要用在电力设备上接电接地,接线线夹采用平口螺旋式,接地方式采用接地线夹(接母排和铜排式)。低压接地线,分为室内设备用接地线和室外线路接地线两种,一般低压线路采用三相四线制。如果用于室外,室外线路多采用双簧式,接地方式采用入地地丁方式,安装在房屋最高点,埋好引下线,引下线的连接一定要牢靠,接地线尽量垂直,埋地两米深,在散点盐,进行泥土的回填。

注意事项

按被保护建筑物的面积,高度,所在地雷暴日及地埋环境校正系数,建筑物使用性质等选择避雷物,并且确定避雷物立杆高度。安装时各部件间要连接可靠,安装完成后,各连接处或金属表面涂镀层有损伤处,应做好防锈处理。避雷用具应通过引下线与女儿墙上的避雷带或者地网连接,要求接地电阻值不能超过10欧姆。在土壤电阻率高的地区,可以适当的放宽对接地电阻的要求。避雷器投入使用后,要定期检查各部分连接是否牢靠,引下线与接地系统连接是否可靠。

通过小编的说明,相信大家也对防雷接地设施的施工有所了解,希望这能通过这篇文章增进大家对防雷的认识。

土巴兔在线免费为大家提供“各家装修报价、1-4家本地装修公司、3套装修设计方案”,还有装修避坑攻略!点击此链接:【】,就能免费领取哦~

避雷器在电力系统应用中的问题分析论文

摘要:文中阐述了避雷器自身防护问题及其对电力系统的影响,简单的论述了避雷器的保护特性,分析了氧化锌避雷器在应用中的问题及解决问题的技术措施,探讨了防雷界的热点问题。

关键词:避雷器特性应用问题分析技术措施

1.应用中的问题探讨

避雷器自身过电压防护问题

避雷器是过电压保护电器,其自身仍存在过电压防护问题。对于能量有限的过电压如雷电过电压和操作过电压,避雷器泄流能起限压保护作用。对能量是无限(有补充能源)的过电压,如暂态过电压(工频过电压和谐振过电压的总称),其频率或为工频或为工频的整数倍或分数倍,与工频电源频率总有合拍的时候,如因某些原因而激发暂态过电压,工频电源能自动补充过电压能量,即使避雷器泄流过电压幅值不衰减或只弱衰减,暂态过电压如果进入避雷器保护动作区,势必长时反复动作直至热崩溃,避雷器损坏爆炸,因此暂态过电压对避雷器有致命危害。如果已将全部暂态过电压限定在保护死区内不受其危害的避雷器,称之为暂态过电压承受能力强,反之称暂态过电压承受能力差。碳化硅避雷器暂态过电压承受能力强,但由于运行中动作特性稳定性差,常因冲击放电电压(保护动作区起始电压)值下降,仍可能遭受暂态过电压危害。无间隙氧化锌避雷器因其拐点电压(可近似地把参考电压当作拐点电压)偏低,仅~(最大相电压),而有些暂态过电压最大值达~,故有暂态过电压承受能差的缺点。对暂态过电压危害有效防护办法是加结构性能稳定的串联间隙将全部暂态过电压限定在保护死区内,使避雷器免受其危害。串联间隙氧化锌避雷器有此独具优点。

避雷器自身对电力系统不安全影响

保护间隙和管型避雷器在间隙击穿后,保护回路再也没有限流元件,保护动作都要造成接地故障或相间短路故障,保护作用增多电力系统故障率,影响电力系统的正常、安全运行。应用氧化锌避雷器,从根本上避免保护作用产生接地故障或相间短路故障,且不用自动重合闸装置就能减少线路雷害停电事故。

避雷器其连续雷电冲击保护能力

有时高压电力装置可能遭受连续雷电冲击,连续雷电冲击是指两次雷电入侵波间隔时间仅数百μs至数千μs,间隔时间极短。碳化硅避雷器保护动作既泄放雷电流也泄放工频续流,切断续流时耗最大达10000μs,一次保护循环时间要远大于10000μs才能恢复到可进行再次动作能力,故碳化硅避雷器没有连续雷电冲击保护能力。氧化锌避雷器保护动作只泄放雷电流,雷电流泄放(小于100μs)完毕,立即恢复到可进行再次动作能力,故氧化锌避雷器具有连续雷电冲击保护能力,这对于多雷区或雷电活动特殊强烈地区的防雷保护尤为重要。

工频能源的浪费

只关注防雷器件泄放雷电流的限(降)压保护作用,轻视或忽视有些器件同时泄放工频电流浪费能源作用。保护间隙或管型避雷器保护动作可能伴随短路电流(几kA至几十kA)对地放电,碳化硅避雷器保护动作有工频续流(避雷器FS型为50A,FZ型为80A,FCD型为250A)对地放电,而造成能源浪费,使用氧化锌避雷器可彻底避免保护作用带来的工频能源浪费。

2.避雷器保护特性

避雷器的保护特性参数

各种型号的避雷器在同用途同电压级时,其雷电残压参数相同或接近,这是因为各生产厂都是按国标规定决定残压值的。有人认为既然雷电残压值一样,它们的保护作用和效果也应是一样的,随意选用哪种型号都可以。这是一种偏见,因为除雷电残压外,还有其它保护参数,如工频放电电压值,冲击放电电压值,是考察避雷器暂态过电压承受能力,保证其长期正常运行的参数;又如是否有雷电陡波残压值,是标示避雷器防雷保护功能完全的重要参数。综合来看,只有串联间隙氧化锌避雷器齐备上述保护特性参数,也就是说它有齐全的防护功能。

避雷器动作特性运行稳定性

碳化硅避雷器保护动作要泄放雷电流和工频续流,动作负载重,经计算每次动作泄放雷电流为~电荷量,工频续流为~电荷量,后者与前者相比一般为11~17倍,且其间隙数量多隙距,常因动作负载重使部分间隙烧毛烧损,另外瓷套外壳脏污潮湿也会影响内间隙电容分布,这些都可能使部分间隙失效而降低冲击放电电压值,即动作特性稳定性差,可能增加保护动作频度,或遭受暂态过电压危害,而加速损坏。串联间隙氧化锌避雷器保护动作只泄放雷电流而无续流,动作负载轻,间隙不需具有灭弧及切断续流能力,故间隙数量特少,3~10kV避雷器仅一个间隙,35kV避雷器为3个间隙串联,间隙的工频放电电压值与碳化硅避雷器相同,符合GB7327规定,故间隙隙距大,动作特性可保持长期运行稳定。

串联间隙氧化锌避雷器

碳化硅避雷器因其间隙结构(隙距小,数量多)带来一些缺点:如没有雷电陡波保护功能;没有连续雷电冲击保护能力;动作特性稳定差可能遭受暂态过电压危害;动作负载重寿命短等。无间隙氧化锌避雷器因其拐点电压较低,有暂态过电压承受能力差,损坏爆炸率高和寿命短等缺点。串联间隙氧化锌避雷器既有间隙又用ZnO阀片,其间隙结构不同于碳化硅避雷器,因其间隙数量少,当过电压达到冲击放电电压时间隙无时延击穿,同时因隙距大动作特性稳定,故它可避免碳化硅避雷器间隙带来的一切缺点。串联间隙氧化锌避雷器的间隙已将全部暂态过电压限定在保护死区内免受其危害,故它可避免无间隙氧化锌避雷器因拐点电压偏低带来一切缺点。串联间隙氧化锌避雷器仍有前两种避雷器保护性能优点,而避免它们的缺点。

避雷器运行工况监测

避雷器失效的主要特征是泄漏电流增大,运行中不易发现,有可能长时带病运行,以致扩大事故,故有必要监察其运行工况。碳化硅避雷缺乏监察手段,靠每年定期普遍测试筛选淘汰这样作事倍功半,还不能随时剔除失效品。氧化锌避雷器可附带脱离器,当其失效损坏时,脱离器自动动作(30mA时不大于8min)退出运行,以免造成更大损失和事故,提高运行安全可靠性。

3.避雷器应用

避雷器外形尺寸

制造避雷器均按户内外两用条件决定其瓷套绝缘强度,其外形尺寸与阀片材料有关。当其用于架空线路或户外变配电设备时,因其相间距大,避雷器外形尺寸不会带来不良影响。户内手车式开关柜因其体积尺寸较小,避雷器外形尺寸大时会带来不良影响。碳化硅避雷器的SiC阀片其单位通流容量仅为ZnO阀片的1/4,在相同通流能力(5kA)条件下,SiC阀片直径较大,避雷器外径也大;在相同额定电压和残压条件下,碳化硅避雷器高度比氧化锌避雷器大。尤以35kV级的更为显著。如JYN1-35型手车柜的112方案,原用FYZ1-35型无间隙氧化锌避雷器,高仅650mm,装在柜后部隔室内简易手车上,上部有隔离插头,因该产品已停产,工程设计坚持改用FZ3-35型碳化硅避雷器,高1500mm,隔室高度不够,只得将母线室与隔室间隔板取消,避雷器直接与主母线相联,这样避雷器的测试或更换必需在整段主母线断电下进行,运行维护困难,而避雷器外径较大,相间空气净距不够,加装的相间绝缘隔板,有老化受潮绝缘事故隐患。氧化锌避雷器外径和高度相对较小,35kV级还可作成悬挂式,如Y5CZz-42/110L型串联间隙氧化锌避雷器,高度仅640mm。小型化避雷器更有利于手车柜内安装使用。

避雷器性能价格比

无间隙氧化锌避雷器的阀片运行中长期承受电网电压,工作条件严酷,产品制造时要对阀片严格测试筛选,合格率低成本高,故价格也高;因它有暂态过电压承受能力差的致命弱点,不适于在我国3~35kV电网中推广使用。串联间隙氧化锌避雷器因有间隙,大大改善阀片长期工作条件,产品制造时对阀片测试筛选要求相对低些,合格率高成本低,价格也就便宜,串联间隙氧化锌避雷器价格比无间隙氧化锌避雷器普遍便宜,有时也比碳化硅避雷器(如3~10kV的FZ型)便宜,同时它对其它防雷器件都有扬长避短作用,实为当代最先进防雷电器,具有高的性能价格比,是避雷器更新换代的普及和推广产品。

避雷器使用寿命问题

避雷器使用寿命与许多因素有关,除制造质量,密封失效受潮及其它外界因素外,避雷器阀片的老化速度是影响寿命的关键因素。碳化硅避雷器因其动作和负载重,续流大,动作特性稳定差,可能遭受暂态过电压危害等原因,加速阀片老化,寿命不长,一般7~10年,甚致有仅3~5年的。无间隙氧化锌避雷器的阀片长期承受电网电压,工作条件严酷,拐点电压低,动作频度大,还可能遭受暂态过电压危害,温度热损伤等原因,迅速加快阀片老化,寿命较短,有的比碳化硅避雷器还短。串联间隙氧化锌避雷器的间隙可保证阀片只在过电压保护动作过程承受高电压,时间极短(100μs内),在其它情况下阀片对于电网电压,或处于隔离状态(纯间隙时),或处于低电位状态(复合间隙电阻分压),大大改善阀片长期工作条件,还可免受暂态过电压危害和温度热损伤,保证阀片温度不超过55℃,从而保证避雷器寿命达20年以上。

4.氧化锌避雷器运行中的问题分析

我公司应用氧化锌避雷器始于80年代,运行至今在110KV母线上共发生6起事故,均为氧化锌避雷器本体爆炸,其运行寿命最长达110个月,最短的仅有11个月煴1为我公司110KVⅢ段母线避雷器爆炸统计表。

从运行时间上、安装的环境、气候、及生产厂,对损坏的氧化锌避雷器进行技术分析,造成氧化锌避雷器运行中爆炸的原因可归纳如下几项:

氧化锌避雷器的密封问题

氧化锌避雷器密封老化问题,主要是生产厂采用的密封技术不完善,或采用的密封材料抗老化性能不稳定,在温差变化较大时或运行时间接近产品寿命后期,造成其密封不良而后使潮气浸入,造成内部绝缘损坏,加速了电阻片的劣化而引起爆炸。

电阻片抗老化性能差

在氧化锌避雷器运行在其产品寿命的后期,电阻片劣化造成泄漏电流上升,甚至造成与瓷套内部放电,放电严重时避雷器内部气体压力和温度急剧增高,而引起氧化锌避雷器本体爆炸,内部放电不太严重时可引起系统单相接地。

瓷套污染

由于工作在室外的氧化锌避雷器,瓷套受到环境粉尘的污染,特别是设置在冶金厂区内变电所,由于粉尘中金属粉尘的比例较大,故给瓷套造成严重的污染而引起污闪或因污秽在瓷套表面的不均匀,而使沿瓷套表面电流也不均匀分布,势必导致电阻片中电流IMOA的不均匀分布(或沿电阻片的电压不均匀分布),使流过电阻片的电流较正常时大1—2个数量级,造成附加温升,使吸收过电压能力大为降低,也加速了电阻片的劣化。

高次谐波

冶金企业电网随着大吨位电弧炉、大型整流、变频设备的应用及轧钢生产的冲击负荷等的影响,使电网上的高次谐波值严重超标。由于电阻片的非线性,当正弦电压作用时,还有一系列的奇次谐波,而在高次谐波作用时就更加速了电阻片的劣化速度。

抗冲击能力差

氧化锌避雷器多在操作过电压或雷电条件下发生事故,其原因是因电阻片在制造工艺过程中,由于其各工艺质量控制点控制不严,而使电阻片的耐受方波冲击能力不强,在频繁吸收过电压能量过程中,加速了电阻片的劣化而损坏,失去了自身的技术性能。

5.技术措施

针对冶金电网的特点及氧化锌避雷器几次事故分析的.结论,要保证氧化锌避雷器在网上安全可靠运行,应采取以下措施:

设计选型

在设计选型上,应首选有多年稳定运行实践的产品,在选择生产厂时,应选择有先进的工艺设备和完善的检测手段的生产厂,才能保证所选用的氧化锌避雷器具有高的抗老化、耐冲击性能,以使在产品的寿命周期内稳定运行。

在线监测

增设氧化锌避雷器的在线监测仪,并加强对在线监测仪的巡检力度,特别是在雷雨后和易发生故障的部位(有电弧炉负荷的母线段、氧化锌避雷器寿命已到后期)增加巡次数。定期给氧化锌避雷器进行各项电气性能测试及在线监测仪的校验。

防污措施

采用必要的避雷器瓷套的防污措施,如定期清扫或涂以防污闪硅油,在氧化锌避雷器选型上选用防污瓷套型的氧化锌避雷器。

谐波治理

加强电网谐波的治理力度,在有谐波源的母线段增设动态无功补偿和滤波装置,以使电网的高次谐波值控制在国家标准允许范围内。

技术管理

加强对氧化锌避雷器的技术管理工作,即对运行在网上的每一只氧化锌避雷器建立技术档案,对出厂报告、定期测试报告及在线监测仪的运行记录均要存入技术档案,直至该避雷器退出运行。

据国外有关技术资料统计,氧化锌避雷器损坏的原因有雷电和操作过电压,受潮、污闪、系统条件、本身故障等,但仍有一定比例损坏的原因不详,故仍有其在运行中对事故原因不明确的问题。又因氧化锌避雷器的劣化速度的离散性,及雷电、操作过电压、谐波、运行环境等的随机性,都决定着氧化锌避雷器的安全运行的可靠性,故需在今后的工作实践中去研究、实验、探索和总结,以使得其在运行中的不安全因素可得以预防和完善。

防雷接地检测等电位连接应用论文

建筑物的综合防雷技术及应用具体内容是什么,下面中达咨询为大家解答。雷击是一种自然现象,它的巨大能量众所周知。几个世纪来,人类对雷击的破坏性的研究、探索和采取预防的措施,已经有了一套比较成熟的理论。从EMC(电磁兼容)的观点来看,防雷保护由外到内应划分多级保护区。最外层为0级,是直接雷击区域,危险性最高,主要是由外部(建筑)防雷系统保护,越往里则危险程度越底。保护区的界面划分主要通过防雷系统、钢筋混凝土及金属管道等构成的屏蔽层而形成,从0级保护区到最内层保护区,必须实行分层多级保护,从而将过电压降到设备能承受的水平。一般而言,雷电流经传统避雷装置后约有50%是直接泄入大地,还有50%将平均流入各电气通道。总体防雷原则是:1.将绝大部分雷电流直接接闪引入地下泄散(外部保护);2.阻塞沿电源线或数据、信号线引入的过电压波(内部保护及过电压保护);3.限制被保护设备上浪涌过压幅值(过电压保护)。这三道防线,相互配合,各行其责,缺一不可。一、建筑物的综合防雷技术应用(一)铁路站场铁路站场直击雷防护重点区域是通信楼、信号楼和户外岔群咽喉区设备。1.通信楼直击雷防护利用通信楼附近的高约45米微波塔,在塔顶上安装IF3避雷针,避雷针安装高度超出塔顶米。经计算,避雷针对地面的保护半径可达119米。引下线采用截面大于12mm×4mm的镀锌扁钢。防雷接地装置接地电阻小于1欧。2.信号楼直击雷防护利用被保护建筑物信号楼,高度约为10米,在信号楼顶部安装IF3避雷针,针的安装高度超出楼顶5米。经计算,保护半径可达109米。楼顶预埋350mm×350mm×10mm厚钢板,便于焊接避雷针底座,从底座延相反方向焊接引出两条引下线,引下线采用大于8mm的圆钢沿楼外墙引下入地,与楼的接地环相连。防雷接地装置接地电阻小于1欧,将避雷针与接地装置贯通。3.户外岔群咽喉区直击雷防护铁路站场岔群咽喉区的特点是设备分布较为集中,岔群咽喉区段长度约145米,在岔群咽喉区附近各建立12米高的铁塔,塔顶安装IF3避雷针。经计算,保护半径可达111米。引下线采用截面大于12mm×4mm的镀锌扁钢。防雷接地装置接地电阻小于10欧。(二)民用机场民用机场的防雷和防雷击电磁脉冲和内部过电压的保护的设计与施工既要可靠地设计建筑物外部的防雷击装置,又要完善考虑建筑物内部的大量电子信息设备的防雷击电磁脉冲和内部过电压的保护。下面讨论设计中的一些要点。1.外部避雷系统在机场重要的第一类和第二类防雷建筑物的接闪器以普通针、带、网相结合为主。如建筑物本身无法实施普通的避雷技术措施,可采用国外先进的提前放电避雷针。在防雷建筑物的外防雷系统的设计时,应实现总等电位连接和联合接地。考虑实际应用效果,引下线可考虑使用焊接的主承重柱内的钢筋引下线逐点检查核实。2.建筑物内部防雷击电磁脉冲和内部过电压保护的设计应特别重视对由低压电缆引入的雷击电磁脉冲的防护,依据《建筑物防雷设计规范》和IEC61312—1《防雷电电磁脉冲设计的一般原则》以及相关国家、行业标准,对于安装有大量电子设备(引入PE线的金属外壳I类耐过压水平用电设备,依据IEC664-1)的低压配电系统,根据防雷分区的定义结合等电位连接的作法,对其防雷电电磁脉冲进行分级设计。二、测报工作中防雷技术的应用(一)水文测报系统水文报汛是在规定的时间内进行,在时间上没有选择的余地。水文缆道架设地野处,加之缆道的主索、工作索等均是钢材,属导电体,易受雷击,为不影响水文测验,必须对缆道进行防雷避雷设施建设。1.水文缆道设施防雷避雷水文缆道跨度较小,可采用避雷针防雷;跨度较大时,避雷针则无法兼顾整个跨度缆道,采取避雷线的方式避雷。在缆道主杆上端架设一个高3m以上的避雷塔,然后在避雷塔安装避雷线,使避雷线、钢支架用扁钢与地网连接。要求避雷线采用截面积不小于35m㎡的镀锌钢绞线;引下线优先采用直径不小于8mm的圆钢,地网电阻不大于4Ω。缆道感应雷的防护主要是依靠电源防雷,信号防雷,合理的地网铺设等措施可减少或杜绝感应雷的影响。长江委水文局上游局的大多水文站均采用在左右岸钢支架上端架设一个高3~5m的避雷塔,安装避雷线,并与地网连接,防雷避雷效果明显。2.水位、雨量仪器防雷避雷采用防雷针、引下线、地网的防雷系统来防止水位、雨量仪器直接雷击。由于水位、雨量观测在野外进行,其观测的设备;雨量筒、卫星天线、太阳能板都安装在自记井顶部(自记井顶部最大直径不超过2m),因此,避雷针也只能安装在自记井顶部。假如卫星天线的高度为,当避雷针高度则为时,可将天线置于以避雷针为圆心、半径约3m的有效保护范围内(避雷针的保护角度按60°算,避雷针最好安装在海事卫星天线的东北方向,因西南方向为卫星登陆方向)。为避免电源线将感应雷传入仪器,采用太阳能电池浮充供电。水位、雨量信息传输的信号线采用屏蔽线,将信号线通过PVC套管从地下引入报汛站,报汛站通过PSTN或网络将水位、雨量信息传送至水情分中心,报汛站还可通过备用信道;海事卫星(或北斗卫星)直接将水位、雨量信息发送至水情分中心。3.水情分中心防雷系统水情分中心一般都建设在大、中城市。地理、地质条件都给地网的布设增加了困难,但避雷针的安装严格按照60度保护角的要求安排避雷针与卫星天线、太阳能板的距离。(二)天气雷达天气测报系统雷达的施工建设工作中同样需要考虑防雷避雷,科学工作者在建设思茅新一代天气雷达中应用了特别的综合防雷技术,并对具体设计工作做了报道与分析。1.接闪采取了避雷针、带组合保护的方式:既在雷达探测楼顶部距天线罩外缘处等圆周、等间距安装4棵等高10m的玻璃钢避雷针,并沿屋面女儿墙顶部安装架空高度为的避雷带,使雷达天线和建筑物处以避雷针、带组合保护的直击雷防护区。2.屏蔽采取了沿机房四周墙体及窗框敷设150cm×150cm的金属屏蔽网格,把机房内电气设备“包围”起来,并做好各类设备外露可导电部件的接地,使室内雷达设备处以第一、二、三层屏蔽防护区内。3.均压连接采取的方法是;从建筑物的基础开始,逐层逐项地将同一层面、同一入口处和雷电防护区交界点的金属构件作等电位连接,形成等电位连接网络。均压连接是一项比较烦杂的工作,是防雷设计与施工质量的主要评判因素之一。4.浪涌保护采用电压开关型和电压限制型浪涌保护器进行防护。供电系统采取3级防护;SPD1安装在距雷达站100m处的变压器低压侧电源总配电箱上,在三根相线上选用I级分类试验用冲击电流Iimp通过幅值电流50KA(10/350μs)的SPD;SPD2安装在雷达站建筑物配电盘上,在三根相线和中性线上选用标称放电电流40KA(8/20μs)的SPD;SPD3安装在雷达主机房分配电盘上,在三根相线和中性线上选用标称放电电流10kA(8/20μs)的.接地天气雷达站的接地处理遵循“共地不共线”的接地原则,即将防雷地、电源地、电源保护地、防静电地和逻辑地等各种接地分别就近就便汇入一个合格的公共接地网。天气雷达站的接地,除利用建筑物的自然接地体外,还增设了约5000人工辅助接地体,形成的公共接地网接地电阻为Ω,满足了天气雷达站在土壤电阻率条件下对接地电阻值的要求。三、电信系统的综合防雷技术应用防雷接地不但是建筑物必须考虑的内容,电气系统和电子设备也必须考虑防雷。(一)有线电视系统CATV系统的防雷接地应包括3个部分:前端、干线(含超干线)和分配系统。1.前端部分的防雷接地前端机房一般不是独立的建筑,因此,整个建筑物的防雷接地系统可以保护前端机房内系统设备的安全,故不必重新做防雷接地,但有几点须引起注意:雷电可能从接收天线串入前端系统;播出机房地板须采用防静电地板,信号电缆与电力电缆分沟敷设;在电力线明线引入时,雷电有可能从电源网串入。2.干线部分的防雷接地CATV系统的干线(含超干线)部分包括电(光)缆和干线设备(如放大器或光接收机等)两项内容,该部分置于室外,必须考虑防雷。电(光)缆的防雷接地对于走地下管道的电(光)缆,应在引下和引上处将金属管道或电缆金属外皮与防雷接地装置相连;市区架空电(光)缆吊线的两端和架空电(光)缆线路中的金属管道均应接地;郊区旷野的架空电(光)缆线路要在分支杆、引上杆、终端杆、角深大于1m的角杆、安装放大器的电杆及直线线路每隔10~15根电杆上加装避雷针,吊线应接地处理,接地装置用35mm×35mm×2000mm角钢或直径10mm以上圆钢,埋深2m。干线设备的防雷接地光接收机、干线放大器和供电器的外壳均应就近接地,但不得与电源变压器和有线广播的接地线相连;对需要外线电源的放大器、供电器,应按防雷标准要求增设电源避雷器。(二)机房系统1.等电位连接和共用接地系统对于机房系统防雷设施,等电位连接的关键是在信息系统机房内布设星形结构(S型)或网形结构(M型)或S型与M型组合的等电位连接网络,使得机房内的电气和电子设备的金属外壳、机柜、机架、屏蔽线外层、及各种电涌保护器(SPD)接地端均能够实现最短的距离就近与等电位连接网络连接。优化接地型式的设计应选择一些导电性好、热稳定性强、耐腐性和承受雷电流能力高的接地材料,如高效防腐降阻剂、铜、铸钢接地极、离子接地极等。2.屏蔽雷电电磁场强度的衰减计算能为信息系统设备布置及采取相应的屏蔽措施提供指导意见。根据计算结果信息系统的主机房一般应选择在大楼的低层中心部位,信息系统设备应尽量远离建筑物的外墙结构柱,设置在雷电防护的最高防护级别区域内。3.电涌保护器的选择和应用低压配电系统SPD选择和配置能量配合有使用退耦元件和不使用退耦元件的配合、有使用触发型SPD的配合、还有两个电压开关型SPD间的配合、电压开关型和限压性SPD间的配合、两个限压型SPD间的配合、末级SPD与被保护设备间的配合等多种配合方式。尽管有了正确的能量配合,如果SPD不是安装在防雷区界面和被保护设备上或其附近,则设备的端子上仍可能出现损害。其原因在于SPD与被保护设备间的线路之间可能引起振荡,这种振荡可能导致超过SPD残压两倍的高电压而损坏设备。信号线路SPD选择和配置信号线路SPD应根据被保护设备的工作电压、接口类型、特性阻抗、插损、功率、信号传输速率、频带宽度及传输介质参数选用插损小、限制电压不超过设备端口耐压的SPD。天馈线路SPD选择和配置天馈线上选用的SPD最大传输功率应为平均功率的倍。其它参数,如工作频率、驻波、插损、特性阻抗、接口等均应符合系统的要求。更多关于工程/服务/采购类的标书代写制作,提升中标率,您可以点击底部官网客服免费咨询:

建筑物防雷是由外部防雷设施和内部防雷设施构成,外部防雷设施包括屋顶接闪器(避雷带,接闪杆,避雷针等)、引下线、户外接地网,内部防雷设施就是室内等电位连接(一般可和电气设备的保护接地、防静电接地共用,说得简单些就是室内所有主要金属设备、电气设备外壳、管道等都接到室内接地网上)。

机柜电台防雷模块地线接什么地方

接地连接:其与等电位连接都有共同之处,降低电位差,但当两者之间的距离能得到保障的时候,是可以不用连通的。

避雷器检测论文

移动通信基站的防雷与接地问题探讨工学论文

摘要: 本文论述了移动基站防雷接地系统经常出现的问题,介绍了移动通信基站防雷接地的重要性,防雷接地系统的构成和基本要求,并结合多年运维经验提出根据实际情况设计移动通信基站防雷接地系统的设计思想。

关键词: 移动通信;基站;防雷;接地

简介由于移动通信基站的天线设置大多安装在建筑物的房顶上,还有一部分安装在铁塔上,相对周围环境而言,形成十分突出的目标,从而导致雷击概率增多。通信设备损坏,耗费了大量人力财力。怎样才能有效地预防雷害,确保移动通信基站设备和工作人员的安全呢?几年来的维护经验告诉我们:必须根据每个基站的实际情况设计移动通信基站的防雷接地系统,实施基站针对性防雷。

1认清移动基站雷害的主要原因

移动基站防雷是一个复杂的系统工程,过去我们按照防雷理论[1],尽量提高基站防雷系统的泄流能力,选用了80kA甚至100kA的大型防雷器,但是防雷效果却不尽人意,经常出现基站防雷器没有明显动作,基站设备却已经发生损坏[2]。是防雷器不好吗?不,防雷器都是检测合格的入网产品。原因是没有按照基站的实际情况设计防雷系统。经调查统计了黑龙江省近两年来的雷击事故,得出一条重要数据;基站内设备被直击雷和雷电感应破坏的概率为零。这是因为基站设备包括基站室外电力变压器的位置普遍较低[3],完全处于建筑防雷设施或铁塔以及架空线路避雷系统和建筑防雷等外围的避雷系统泄放,所以基站设备很难遭到直击雷损害。

2防止地电压反击是基站防雷接地的主要课题

当雷电流基站附近的避雷器对地泄放时,由于接地电阻的存在必然引起基站工作地的电位升高,基站直流负荷如BTS电源、开关电源的监控单元、基站的动力环境监控器等设备相对远端地一般都存在寄生电容,这些设备一端接工作接地,无流的远端地与基站的工作接地间存在电位差,因而产生差模脉冲电压[5]。当超过设备绝缘耐压的容许限度时必然造成设备的损坏。基站的单相交流负荷如基站空调、照明等设备的零线接在变压器的交流地上,当雷电流沿基站附近的避雷器对地泄放时,变压器的交流地和交流重复接地电位也会升高,因此基站的单相交流设备也同样存在地电压反击的问题。

若把基站设备与接地有关的电路简单等效为线路电阻、线路寄生电感(可忽略不计)、线路负载(如传感器、BTS、空调、灯具等)、终端对远端地寄生电容组成的串联回路。假设基站的冲击接地电r为2欧姆,防雷器对地的泄放电流为2kA,这时基站的接地排的瞬间电压为U=1×r=4kV,可见负载两端的瞬间浪涌电压可达4kV,如不采取措施,必然造成设备损坏。

3因地制宜消减反击电压

怎样才能避免地电压反击造成的`损失呢?一般很自然会想到使用交流过压保护器和直流浪涌抑制器,即在交流变压器的低压侧、基站交流配电箱的地零间加装交流过压保护器;在直流负载的电源输入端加装浪涌抑制器。所有交流过压保护器和直流浪涌抑制器必须靠近被保护的设备安装,避免被保护设备由于接地或电源引线过长引起脉冲反射。除此之外一个非常重要的问题就是将基站的工作接地与室外避雷器接地在基站地网上的引接点分开焊接,这样可以大大降低基站工作接地母排的电压浪涌幅值。众所周知,雷电电流沿地网泄放时,在避雷器引下线与地网连接点附近土壤内形成一个强电位场,距离越近电压越高。将基站工作接地与室外避雷器接地分开,可以大大降低基站的反击电压。所以YD5068-98《移动通信基站防雷与设计规范》明确指出:基站工作地与防雷地在基站联合接地网上的引接点距离不应小于5m,条件允许时宜间距10~15m。实际上除电力线路外,基站的铁塔遭雷击次数最多,与铁塔共用接地网的基站经常受到地电压反击的损害,如果铁塔地网边缘距离基站大于5m,应在基站附近另建环形工作接地网;条件差的基站可以沿铁塔地网与基站工作接地引接线,补设接地桩;只能利用铁塔地网的基站也应把铁塔避雷接地的引接点与工作接地的引接点分别在对角塔基上安装。

对于山项基站尤其应注意将基站的工作接地与铁塔避雷接地及站基室外接地分开,因为山顶基站的接地电阻较大,接地引线较长,雷电流泄放相对缓慢,所以地电压反击比较严重。

降低基站接地电阻也有利于电压反击事故。接地电阻较大的山上基站,可利用塔基钢筋、蓄水池、无爆炸和电击危险的金属管路等自然接地体,埋设地桩有困难的山上基站也可从塔基沿山体的自然沟壑,最好选择阴暗潮湿的地方,制作横向辐射接地网,辐射接地网长度应小于30m,塔基四周辐射的横向接地网越多也有利于雷电散流。

4适当地选用电源线路保护空开

防止雷电波侵入避雷的响应特性有远近软硬之分:气体放电管和火花间隙防雷器是基于斩弧技术的角形火花隙和同轴放电火花隙,当线中电压超过防雷器的击穿电压后,防雷器的绝缘电阻立刻急剧下降,放电能力较强,残压相对较高,恢复电压低于原来的击穿电压,属于硬响应特性;属于软响应特性的压敏电阻和浪涌抑制二极管,其特点是响应时间短,放电电流小,残压低,而且恢复电压基本不变。硬响应特性的防雷器工频后续电流和防雷器绝缘劣化可能造成线路短路,所以防雷器前面应该配置过流保护空气开关或熔丝。其额定电流应小于防雷器的最大短路允许强度。如果主电路保护空开关大于防雷器的最大保险丝强度,应设避雷器分路保护空开。

5实现分级防雷

防雷器的残压是保护基站设备的最重要参数,一般来讲,泄流能力强的防雷器,响应时间长,残压高。世界上没有任何一种防雷器能满足所有混合雷电冲击波、残压以及响应时间指标要求,所以应根据基站电源设备的绝缘等级划分防雷层次,实现多级防护,对雷电能量逐级减弱,使各级防雷器残压相互配合,最终使过电压值限制在设备绝缘强度之内。另外多级防护对于某一级防雷器失效、防雷器的残压不配合设备绝缘强度等也是必须的。我们认为应该结合YD5078-98《通信工程电源系统防雷技术规定》和基站的实际情况,从交流电力网高压线路开始,根据基站主要电源配套设备的耐雷电冲击指标和防雷器残压要求,采取分级协调的防护措施,进行基站的防雷系统设备。避雷器的直流1mAA参考电压是我们选择避雷器的绝缘要求,选用时应考虑电网的电压波动上限值和操作过电压远小于直流1mA参考电压。

实现各级防雷器的能量分配与电压配合的要点在于利用两级防雷器之间线缆本身的感抗。电缆本身的感抗有一定的阻碍电流及分压作用,使雷电流更多地被分配到前级泄放。当保护地线与其它线缆紧贴敷设或处于同一条电缆之内时,要求两级防雷器之间线缆长度在15m左右,当防雷器接地线与被保护电缆有一定距离(>1m),这时要求线缆长度大于5m即可。在一些不适合采用线缆本身作退耦措施的,如两级防雷器靠近或线缆长度较短时,可利用专门的退耦器件,这是无距离要求。

参考文献

[1]YD5068-98移动通信基站防雷与接地设计规范[S].

[2]张殿富.移动通信基础[M].北京:中国水利水电出版社.

[3]金山,刘吉克,陈强.YD/T 1429-2006通信局(站)在用防雷系统的技术要求和检测方法[S].2006.

[4]曹和生,吴少丰,匡本贺.GB/T 21431-2008建筑物防雷装置检测技术规范[S].2008.

[5]张农.关于基站防雷接地的问题[J].邮电设计技术,2004(4).

电力系统防雷技术应用研究论文

摘要: 雷击对电力系统的破坏会产生严重后果,因而电力系统内外部的防雷要求也越来越高了。因为科技进步使得防雷技术不断发展,而雷电这种自然现象对电力系统的危害还是会一直存在,故而要想让电力系统安全供电,重点还是应该做好防雷工作。文章主要通过雷电对电力系统运行的影响论述来探讨电力系统防雷技术的应用,以期为电力系统的安全运行提供有益建议。

关键词: 电力系统;防雷技术;应用

作为自然现象之一的雷电会对电力系统造成击穿、线路损害、设备失灵等不同的损坏,而且还雷电涌流还会进入系统二次设备,让相关保护装置出现失灵之类的恶性事故,由此严重威胁电力系统的安全运行。也正是因为如此,人们一直在研究雷电及相关的防雷技术,通过大量的研究来研发更为有效的雷电保护装置,为电力系统的安全运行保驾护航。

1雷电与电力系统运行

尽管雷电属于自热现象,但是却是电力系统运行中的不可抗力,雷电是因为正电极存在负电荷而产生,能够在电场周围形成强大的高压,让空气绝缘被影响,受到损坏,而雷电间各种电极不断进行大量放电,尽管放电时间短且不会超过100,不过电流强度却高达100000A。闪电在放电中产生电火,在短时间内周围空气突然膨胀后爆鸣,从而产生了自然雷电现象。电力系统很容易被雷电所袭击,电力、设备与系统都会被电磁、热力影响,造成线路、电线等出现熔毁问题。并且电雷带来的高强度电压、电磁会极大影响电路与电线的绝缘体,只要存在高强度电压,电压强度就会很大,由此出现闪络问题,而这种问题在电力设备、线路等绝缘物体上发生就会让电力系统设备与线路出现损坏。尽管雷电会破坏电力系统的安全运行,不过只要采取合理的防范方法,就能够预防雷电灾害。当下,避雷针(线)安装、电力系统设备绝缘性提升、避雷保护装置设置等是比较常用的雷电防护措施。

2防雷技术在电力系统的应用

避雷器作为雷电流泄放通道,还可以被看成是等电位连接体,安装要对地,而在线路上并联,一般都处于高阻抗环境。雷击可以在一瞬间被避雷器导通,把雷电电流引向地上,同时让设备、线路、大地在等电位上,让电力系统不会因为强电势差而被损坏。雷击能量就打,只使用避雷器是无法完全把雷电流引入地上,也会损坏自身。所以,应该将功能不一样的避雷过压保护器件放置在各个电磁场强度空间。不同器件分工合作,让电流入地,保证低残压,也让避雷器的使用寿命更长。

电源系统防雷

所谓电源系统防雷就是利用避雷过压保护计算机系统电源与相关的交流配电部分,蒋避雷器安装在雷电波可能侵入的电力进线部位。电源系统有很多不一样保护级别。电源避雷器的'选择应该要与额定通流容量、电压保护水平相适应,让避雷器能够抵御雷电冲击。电影避雷器中残压特性十分重要,要想避雷器的保护效果更好就应该要使其残压更低。另外,必须兼顾避雷器能够具有很高的最大连续工作电压。原因就是如果最大连续额定工作电压不够高,避雷器会很快损坏。电源避雷器需要贴上失效警告指示,还有方便监管、维护的遥测端口。电源避雷器要有阻燃作用,防止失效与自毁情况下的起火问题。电源避雷器通常都具有失效分离装置。如果不能避雷就会自动断开电源系统,而且电源系统也会正常运行。在安装电源避雷器的过程中,要注意和电源系统的连接线越短越好,所使用的阻燃型多股铜导线的横截面面积不能超过25mm2,要紧密地并排,可以绑扎布放。避雷器接地线所使用的25mm2到35mm2的阻燃型多股铜导线,要么尽量就近入地,要么就近和交流保护接地汇流排或者直接和接地网连接。

通信系统防雷

一般数据线路上会串联接口避雷器,而且是以不影响数据传输作为应用依据。数据接口的工作带要宽、物理接口要合适,并且还要考虑到接口速率,以更好地保护避雷器。数据设备接口的连接为了增加插损,要少用转接方法,这样才可以让信号更好地传输。而在选择速率高的数据设备接口时,要考虑起驻波比、极间电容、漏电流小、响应时间快的数据避雷器。从信号工作电压层面选择动作电压、限制电压合理的数据接口,以保护避雷器。选择抗雷电冲击力强的数据避雷器时,应该要充分了解设备接口抗雷电要求。数据避雷器的接地连接一定要有效,就近连接接地线与被保护数据设备的地线,而接地线截面不能低于25mm2。

机房接地改造

接地系统在电力系计算机系统避雷过压保护技术中有十分重要的作用。防静电接地、防雷接地、保护接地等都属于接地技术。这些接地的用途、意义、要求都不一样,糖醋分设每个独立接地体是较为常见的,不过,由于雷击环境中,防雷接地系统和别的接地系统有电势差,所以很容易出现反击事故,让电子设备被损坏。所以,需要等电位连接全部接地系统。

3结语 总之,电力系统在不断发展,而且被运用在社会生产生活的各个行业,因此其作用极大。我国经济发展日盛,电量需求巨大,电力供应异常重要。因此,需要对电力系统进行有效保护。一直以来,雷击对电力系统的影响尤甚,因而电力系统中防雷技术的应用受到高度重视。在电力系统防雷技术应用中,我们必须要通过具体的实际情况来采取科学、有效的防雷措施。在对电力系统的防雷工作中,要积极地采取新技术新措施,保证电力系统的正常运行,为人们的生产生活创造安全、稳定的环境。

参考文献:

[1]张金国.电力系统防雷措施研究[J].科技创业家,2013(4):63

[2]王少先.电力系统防雷工程设计浅谈[J].科技资讯,2012(2):51

避雷器在电力系统应用中的问题分析论文

摘要:文中阐述了避雷器自身防护问题及其对电力系统的影响,简单的论述了避雷器的保护特性,分析了氧化锌避雷器在应用中的问题及解决问题的技术措施,探讨了防雷界的热点问题。

关键词:避雷器特性应用问题分析技术措施

1.应用中的问题探讨

避雷器自身过电压防护问题

避雷器是过电压保护电器,其自身仍存在过电压防护问题。对于能量有限的过电压如雷电过电压和操作过电压,避雷器泄流能起限压保护作用。对能量是无限(有补充能源)的过电压,如暂态过电压(工频过电压和谐振过电压的总称),其频率或为工频或为工频的整数倍或分数倍,与工频电源频率总有合拍的时候,如因某些原因而激发暂态过电压,工频电源能自动补充过电压能量,即使避雷器泄流过电压幅值不衰减或只弱衰减,暂态过电压如果进入避雷器保护动作区,势必长时反复动作直至热崩溃,避雷器损坏爆炸,因此暂态过电压对避雷器有致命危害。如果已将全部暂态过电压限定在保护死区内不受其危害的避雷器,称之为暂态过电压承受能力强,反之称暂态过电压承受能力差。碳化硅避雷器暂态过电压承受能力强,但由于运行中动作特性稳定性差,常因冲击放电电压(保护动作区起始电压)值下降,仍可能遭受暂态过电压危害。无间隙氧化锌避雷器因其拐点电压(可近似地把参考电压当作拐点电压)偏低,仅~(最大相电压),而有些暂态过电压最大值达~,故有暂态过电压承受能差的缺点。对暂态过电压危害有效防护办法是加结构性能稳定的串联间隙将全部暂态过电压限定在保护死区内,使避雷器免受其危害。串联间隙氧化锌避雷器有此独具优点。

避雷器自身对电力系统不安全影响

保护间隙和管型避雷器在间隙击穿后,保护回路再也没有限流元件,保护动作都要造成接地故障或相间短路故障,保护作用增多电力系统故障率,影响电力系统的正常、安全运行。应用氧化锌避雷器,从根本上避免保护作用产生接地故障或相间短路故障,且不用自动重合闸装置就能减少线路雷害停电事故。

避雷器其连续雷电冲击保护能力

有时高压电力装置可能遭受连续雷电冲击,连续雷电冲击是指两次雷电入侵波间隔时间仅数百μs至数千μs,间隔时间极短。碳化硅避雷器保护动作既泄放雷电流也泄放工频续流,切断续流时耗最大达10000μs,一次保护循环时间要远大于10000μs才能恢复到可进行再次动作能力,故碳化硅避雷器没有连续雷电冲击保护能力。氧化锌避雷器保护动作只泄放雷电流,雷电流泄放(小于100μs)完毕,立即恢复到可进行再次动作能力,故氧化锌避雷器具有连续雷电冲击保护能力,这对于多雷区或雷电活动特殊强烈地区的防雷保护尤为重要。

工频能源的浪费

只关注防雷器件泄放雷电流的限(降)压保护作用,轻视或忽视有些器件同时泄放工频电流浪费能源作用。保护间隙或管型避雷器保护动作可能伴随短路电流(几kA至几十kA)对地放电,碳化硅避雷器保护动作有工频续流(避雷器FS型为50A,FZ型为80A,FCD型为250A)对地放电,而造成能源浪费,使用氧化锌避雷器可彻底避免保护作用带来的工频能源浪费。

2.避雷器保护特性

避雷器的保护特性参数

各种型号的避雷器在同用途同电压级时,其雷电残压参数相同或接近,这是因为各生产厂都是按国标规定决定残压值的。有人认为既然雷电残压值一样,它们的保护作用和效果也应是一样的,随意选用哪种型号都可以。这是一种偏见,因为除雷电残压外,还有其它保护参数,如工频放电电压值,冲击放电电压值,是考察避雷器暂态过电压承受能力,保证其长期正常运行的参数;又如是否有雷电陡波残压值,是标示避雷器防雷保护功能完全的重要参数。综合来看,只有串联间隙氧化锌避雷器齐备上述保护特性参数,也就是说它有齐全的防护功能。

避雷器动作特性运行稳定性

碳化硅避雷器保护动作要泄放雷电流和工频续流,动作负载重,经计算每次动作泄放雷电流为~电荷量,工频续流为~电荷量,后者与前者相比一般为11~17倍,且其间隙数量多隙距,常因动作负载重使部分间隙烧毛烧损,另外瓷套外壳脏污潮湿也会影响内间隙电容分布,这些都可能使部分间隙失效而降低冲击放电电压值,即动作特性稳定性差,可能增加保护动作频度,或遭受暂态过电压危害,而加速损坏。串联间隙氧化锌避雷器保护动作只泄放雷电流而无续流,动作负载轻,间隙不需具有灭弧及切断续流能力,故间隙数量特少,3~10kV避雷器仅一个间隙,35kV避雷器为3个间隙串联,间隙的工频放电电压值与碳化硅避雷器相同,符合GB7327规定,故间隙隙距大,动作特性可保持长期运行稳定。

串联间隙氧化锌避雷器

碳化硅避雷器因其间隙结构(隙距小,数量多)带来一些缺点:如没有雷电陡波保护功能;没有连续雷电冲击保护能力;动作特性稳定差可能遭受暂态过电压危害;动作负载重寿命短等。无间隙氧化锌避雷器因其拐点电压较低,有暂态过电压承受能力差,损坏爆炸率高和寿命短等缺点。串联间隙氧化锌避雷器既有间隙又用ZnO阀片,其间隙结构不同于碳化硅避雷器,因其间隙数量少,当过电压达到冲击放电电压时间隙无时延击穿,同时因隙距大动作特性稳定,故它可避免碳化硅避雷器间隙带来的一切缺点。串联间隙氧化锌避雷器的间隙已将全部暂态过电压限定在保护死区内免受其危害,故它可避免无间隙氧化锌避雷器因拐点电压偏低带来一切缺点。串联间隙氧化锌避雷器仍有前两种避雷器保护性能优点,而避免它们的缺点。

避雷器运行工况监测

避雷器失效的主要特征是泄漏电流增大,运行中不易发现,有可能长时带病运行,以致扩大事故,故有必要监察其运行工况。碳化硅避雷缺乏监察手段,靠每年定期普遍测试筛选淘汰这样作事倍功半,还不能随时剔除失效品。氧化锌避雷器可附带脱离器,当其失效损坏时,脱离器自动动作(30mA时不大于8min)退出运行,以免造成更大损失和事故,提高运行安全可靠性。

3.避雷器应用

避雷器外形尺寸

制造避雷器均按户内外两用条件决定其瓷套绝缘强度,其外形尺寸与阀片材料有关。当其用于架空线路或户外变配电设备时,因其相间距大,避雷器外形尺寸不会带来不良影响。户内手车式开关柜因其体积尺寸较小,避雷器外形尺寸大时会带来不良影响。碳化硅避雷器的SiC阀片其单位通流容量仅为ZnO阀片的1/4,在相同通流能力(5kA)条件下,SiC阀片直径较大,避雷器外径也大;在相同额定电压和残压条件下,碳化硅避雷器高度比氧化锌避雷器大。尤以35kV级的更为显著。如JYN1-35型手车柜的112方案,原用FYZ1-35型无间隙氧化锌避雷器,高仅650mm,装在柜后部隔室内简易手车上,上部有隔离插头,因该产品已停产,工程设计坚持改用FZ3-35型碳化硅避雷器,高1500mm,隔室高度不够,只得将母线室与隔室间隔板取消,避雷器直接与主母线相联,这样避雷器的测试或更换必需在整段主母线断电下进行,运行维护困难,而避雷器外径较大,相间空气净距不够,加装的相间绝缘隔板,有老化受潮绝缘事故隐患。氧化锌避雷器外径和高度相对较小,35kV级还可作成悬挂式,如Y5CZz-42/110L型串联间隙氧化锌避雷器,高度仅640mm。小型化避雷器更有利于手车柜内安装使用。

避雷器性能价格比

无间隙氧化锌避雷器的阀片运行中长期承受电网电压,工作条件严酷,产品制造时要对阀片严格测试筛选,合格率低成本高,故价格也高;因它有暂态过电压承受能力差的致命弱点,不适于在我国3~35kV电网中推广使用。串联间隙氧化锌避雷器因有间隙,大大改善阀片长期工作条件,产品制造时对阀片测试筛选要求相对低些,合格率高成本低,价格也就便宜,串联间隙氧化锌避雷器价格比无间隙氧化锌避雷器普遍便宜,有时也比碳化硅避雷器(如3~10kV的FZ型)便宜,同时它对其它防雷器件都有扬长避短作用,实为当代最先进防雷电器,具有高的性能价格比,是避雷器更新换代的普及和推广产品。

避雷器使用寿命问题

避雷器使用寿命与许多因素有关,除制造质量,密封失效受潮及其它外界因素外,避雷器阀片的老化速度是影响寿命的关键因素。碳化硅避雷器因其动作和负载重,续流大,动作特性稳定差,可能遭受暂态过电压危害等原因,加速阀片老化,寿命不长,一般7~10年,甚致有仅3~5年的。无间隙氧化锌避雷器的阀片长期承受电网电压,工作条件严酷,拐点电压低,动作频度大,还可能遭受暂态过电压危害,温度热损伤等原因,迅速加快阀片老化,寿命较短,有的比碳化硅避雷器还短。串联间隙氧化锌避雷器的间隙可保证阀片只在过电压保护动作过程承受高电压,时间极短(100μs内),在其它情况下阀片对于电网电压,或处于隔离状态(纯间隙时),或处于低电位状态(复合间隙电阻分压),大大改善阀片长期工作条件,还可免受暂态过电压危害和温度热损伤,保证阀片温度不超过55℃,从而保证避雷器寿命达20年以上。

4.氧化锌避雷器运行中的问题分析

我公司应用氧化锌避雷器始于80年代,运行至今在110KV母线上共发生6起事故,均为氧化锌避雷器本体爆炸,其运行寿命最长达110个月,最短的仅有11个月煴1为我公司110KVⅢ段母线避雷器爆炸统计表。

从运行时间上、安装的环境、气候、及生产厂,对损坏的氧化锌避雷器进行技术分析,造成氧化锌避雷器运行中爆炸的原因可归纳如下几项:

氧化锌避雷器的密封问题

氧化锌避雷器密封老化问题,主要是生产厂采用的密封技术不完善,或采用的密封材料抗老化性能不稳定,在温差变化较大时或运行时间接近产品寿命后期,造成其密封不良而后使潮气浸入,造成内部绝缘损坏,加速了电阻片的劣化而引起爆炸。

电阻片抗老化性能差

在氧化锌避雷器运行在其产品寿命的后期,电阻片劣化造成泄漏电流上升,甚至造成与瓷套内部放电,放电严重时避雷器内部气体压力和温度急剧增高,而引起氧化锌避雷器本体爆炸,内部放电不太严重时可引起系统单相接地。

瓷套污染

由于工作在室外的氧化锌避雷器,瓷套受到环境粉尘的污染,特别是设置在冶金厂区内变电所,由于粉尘中金属粉尘的比例较大,故给瓷套造成严重的污染而引起污闪或因污秽在瓷套表面的不均匀,而使沿瓷套表面电流也不均匀分布,势必导致电阻片中电流IMOA的不均匀分布(或沿电阻片的电压不均匀分布),使流过电阻片的电流较正常时大1—2个数量级,造成附加温升,使吸收过电压能力大为降低,也加速了电阻片的劣化。

高次谐波

冶金企业电网随着大吨位电弧炉、大型整流、变频设备的应用及轧钢生产的冲击负荷等的影响,使电网上的高次谐波值严重超标。由于电阻片的非线性,当正弦电压作用时,还有一系列的奇次谐波,而在高次谐波作用时就更加速了电阻片的劣化速度。

抗冲击能力差

氧化锌避雷器多在操作过电压或雷电条件下发生事故,其原因是因电阻片在制造工艺过程中,由于其各工艺质量控制点控制不严,而使电阻片的耐受方波冲击能力不强,在频繁吸收过电压能量过程中,加速了电阻片的劣化而损坏,失去了自身的技术性能。

5.技术措施

针对冶金电网的特点及氧化锌避雷器几次事故分析的.结论,要保证氧化锌避雷器在网上安全可靠运行,应采取以下措施:

设计选型

在设计选型上,应首选有多年稳定运行实践的产品,在选择生产厂时,应选择有先进的工艺设备和完善的检测手段的生产厂,才能保证所选用的氧化锌避雷器具有高的抗老化、耐冲击性能,以使在产品的寿命周期内稳定运行。

在线监测

增设氧化锌避雷器的在线监测仪,并加强对在线监测仪的巡检力度,特别是在雷雨后和易发生故障的部位(有电弧炉负荷的母线段、氧化锌避雷器寿命已到后期)增加巡次数。定期给氧化锌避雷器进行各项电气性能测试及在线监测仪的校验。

防污措施

采用必要的避雷器瓷套的防污措施,如定期清扫或涂以防污闪硅油,在氧化锌避雷器选型上选用防污瓷套型的氧化锌避雷器。

谐波治理

加强电网谐波的治理力度,在有谐波源的母线段增设动态无功补偿和滤波装置,以使电网的高次谐波值控制在国家标准允许范围内。

技术管理

加强对氧化锌避雷器的技术管理工作,即对运行在网上的每一只氧化锌避雷器建立技术档案,对出厂报告、定期测试报告及在线监测仪的运行记录均要存入技术档案,直至该避雷器退出运行。

据国外有关技术资料统计,氧化锌避雷器损坏的原因有雷电和操作过电压,受潮、污闪、系统条件、本身故障等,但仍有一定比例损坏的原因不详,故仍有其在运行中对事故原因不明确的问题。又因氧化锌避雷器的劣化速度的离散性,及雷电、操作过电压、谐波、运行环境等的随机性,都决定着氧化锌避雷器的安全运行的可靠性,故需在今后的工作实践中去研究、实验、探索和总结,以使得其在运行中的不安全因素可得以预防和完善。